Author: Sarah Beackley

PLC WorkShop Suite for Siemens 505 v4.10 Release Notes

Features

  • Supports integration with FTVersionTrak.
  • Supports the new CTI 2500 Series processors, which can now be selected from the list of supported PLC types.
  • 505 Simulator can now be fully accessed when security is enabled.
  • Application-wide settings can now be accessed from the Application Setup menu item. The Program Setup options “Number of Backup Files” and “Always Show Logic Toolbars” now reside in Application Setup.

Solutions

  • Saving a program in online Address Mode no longer results in an unexpected error.
  • Saving a program in Network Mode with CAMP enabled no longer results in memory errors.
  • Using TEXT instructions no longer causes PLC compile errors.
  • Editing the TEXT instruction in Network Mode no longer results in termination of the program.
  • Programs with file paths greater than 144 characters can now be loaded normally.
  • Attempting to cut, copy, or paste a Special Function program/subroutine containing a PACK instruction (PACK, PACKRS, PACKAA, or PACKLOOP) no longer results in a memory error.
  • Every slot in an I/O base can now be used to initiate a Data Window I/O Fill.
  • Watchdog Timers now display normally in PLC Configuration.
  • Remote bases are no longer cleared when changing the PLC type to a 565.
  • 565 PLCs now return to Run mode properly when a ladder edit is made online.
  • Using indexed addresses in Special Function instruction parameters no longer results in the contents of the address being referenced instead of the address itself.
  • WorkShop now displays a Save As dialog after an attempt is made to save a program to a read-only file.
  • Users are now prompted to set the DP Mode when loading a program that contains COM Profibus configuration by parts.
  • I/O addresses are no longer cleared when merged COM Profibus configuration files match the configuration.
  • End Conditional (ENDC) instructions can now be searched for in the Find dialog.
  • The Help button in the Syntax Checker dialog now links to the proper help topic.
  • I/O Bits of Word no longer erroneously display a Forced state in ladder status.

PLC WorkShop Suite for Siemens 505 v4.00 SP1 Release Notes

Features

  • Entering floating point addresses with the Dot notation in Data Windows does not change the default format type.
  • Minimized Windows within WorkShop are not pushed below the bottom edge of the WorkShop Window.
  • A new “Always Show Logic Toolbars” feature was added to the Program Setup. This feature displays any docked or floating logic toolbars even when focus is on a non-Logic Window (Documentation, Data, Cross Reference, etc.).
  • The contents of the Cross Reference Window can be “refreshed” with valid PID Loop and Analog Alarm addresses.
  • 505 Workshop Quick Start Guide is now installed in the 505 WorkShop installation directory when the 505 Workshop Manuals option is selected. There is also a link to this PDF document added to the start menu.
  • The original online and offline “Edit” security privileges (which allowed editing of both logic in the ladder and Special Function Windows, and values in the Data Windows) have been divided into separate “Edit Logic” and “Edit Data Values” privileges.

Solutions

  • The Replace Table replaces any necessary items in networks containing One-Shot instructions.
  • Programs load and save correctly while online using CAMP through a CTI 2572 card.
  • The last network is saved to the disk file while online in ladder address mode.
  • Clicking the Validate and Enter toolbar button repeatedly and rapidly while online does not terminate WorkShop.
  • Minimizing and restoring WorkShop no longer relocates docked toolbars to the top or left edges of the WorkShop Window.
  • Validating changes in ladder and Special Function windows no longer repositions the logic to display the top of the network that contains the editing cursor.
  • The Unique Address feature now finds the same TC addresses in all types of timers.
  • The Replace Table now correctly replaces ranges of addresses in PID Loops and Analog Alarms.
  • The Cross Reference and Addresses Used features work correctly when online in ladder address mode with PLCs that do not support CAMP.
  • Saving some programs while online using CAMP does not reset the CTI communications card.
  • Updating the Cross Reference Table when connected to the 505 Simulator does not terminate WorkShop.
  • The Security Configurator (FTSecCfg.exe) and site license DLLs are removed when uninstalling WorkShop.
  • The Task Codes Per Scan utility is not longer available when online with the 505 Simulator.

ControlShop v12/29/05 Release Notes

New Feature in 505 Server v2.37

  • Increased communication speeds with CAMP.

Solution in 505 Server, v2.37

  • Eliminated serial communication timeouts.

Solutions in FTLogger, v3.02

  • Documentation Table names, which contain spaces, can now be opened.
  • Coexistence problems between WorkShop and ControlShop have been eliminated when performing installations.

Solutions in FTTrender, v2.02

  • Documentation Table names, which contain spaces, can now be opened.
  • Coexistence problems between WorkShop and ControlShop have been eliminated when performing installations.
  • Eliminated database error following a failure to go online.

Solution in FTAlarm, v4.01

  • Eliminated problem that occurred when older *.ALM files are loaded.

PLC WorkShop Suite for Siemens 505 v4.00 Release Notes

Features

  • Added 505 Simulator to install. Added Simulator tool bar for debugging and I/O simulation.
  • Added Find Previous ability to key word searches in Documentation Window.
  • Increased ladder transfer rates, up to 10 times faster, using TCP/IP and a CTI 2572 Rev. 8.5 and higher or 2572A Rev. 1.41 and higher.
  • Improved editing the Text Instruction in ladder.
  • Updated the PLC type for 530C to include the 530T.
  • Added new 505 I/O and Profibus I/O Fill dialogs to Data Window.

Solutions

  • Add mouse wheel scrolling functionality in ladder for Windows XP.
  • Corrected crashing of Cross-Reference while building the table when TEXT instructions are present.
  • Corrected lockups caused by K registers set to zero while having register type programmed in ladder.
  • Improved search interface to prevent invalid errors.
  • Improved online Open dialog to eliminate informing user of program transfer when program is being opened in a PLC.
  • Corrected online Open or Load so that proper errors are displayed.
  • Corrected stopping of Profibus operations when canceling out of Halt PLC warning dialog when transferring a program online.
  • Corrected appending the *.WDT extension every time a Data Window template is saved.
  • Corrected import of Ramp/Soak steps.
  • Corrected Paste with Rewire to include all addresses including those without documentation.
  • Eliminated removal of the rectangular cursor when using the shortcut key ‘m’ to delete a vertical line.
  • Creating a SmarTune Control Block no longer enables PID Loops.
  • Updated Security settings to restrict editing of K and V values in the Data Window to users with offline edit rights only.
  • Corrected the ability to search the Move Instruction.
  • Corrected the Replace Table to again recognize Box Instructions and all address types.

PLC WorkShop for Siemens S5 v5.12 Release Notes

Solutions

  • When installing WorkShop, the Administrators group is no longer language dependent.
  • Improved compatibility with importing Step5 programs.
  • Corrected problem of an Asterisk displaying in the Tab Title of a new program after completing a File Merge.
  • Increased the number of Data Words and doubles to 2047.
  • Eliminated communication errors from occurring when using statement list status on addresses with an element of 16.
  • Corrected problem associated with opening a new program that uses shared documentation.
  • Within the Data Window, improved the previous address range checking when referencing double words.
  • Eliminated communication time-outs that could possibly occur with the download of large blocks on a 150U processor.

PLC WorkShop Suite for Siemens 505 v3.60 SP3 Release Notes

Solutions

  • Corrected problem with importing address documentation from VP5 files.
  • Improved the method for verifying Administrator privileges for FasTrak and NT Security in computers set up in languages other than English.
  • Corrected problem with searching for instructions and addresses in large programs while online.
  • When cutting and pasting Special Function Programs and Subroutines, the control block number is now changed.
  • Corrected key word search problems, which occurred when the Documentation Window was not sorted by address.
  • Eliminated computer lockup that occurred when attempting to export invalid addresses.
  • Excess data is now truncated when documentation being imported does not adhere to WorkShop limits.
  • Eliminated lockup that occurred when printing non-ladder parts of the program.
  • Eliminated lockup that occurred when a Unique function is performed on a constant.
  • Corrected problems with importing files created in Excel. If a record being imported has an address but no tag description and description comment, the record is not imported. The import process then continues to the end of the file.
  • Corrected problem of windows, which have been minimized, disappearing off of the screen when the logic window is enabled.
  • Corrected problems encountered when deleting multiple loops.
  • The Data Window now prompts user to save changes to Data Template when the Data Window is closed.
  • The Data Window title bar is updated with the template name when the template is saved.
  • Headers can now be imported from FSS files that use shared address documentation.
  • Corrected the search function in 505 I/O to ensure searching all slots in bases.
  • When closing a file after doing configuration changes, the Save Complete Program check box in the Save-by-Parts dialog is checked.
  • Corrected the update in the Data Window when using the mouse scroll wheel.
  • Load and Save functions have been corrected to update program and meter windows in a timely manner. Cancel has been added to both Load and Save Metering dialogs.
  • Corrected problem of multiple copies of the edited network being entered when communication to a PLC is set to a minimum when editing ladder with PLC in edit mode.
  • The time needed to display the SF Directory dialog has been decreased.
  • Workshop correctly identifies mismatched communications over TCP/IP.
  • Corrected lookup when displaying status for compare instructions in large networks.
  • Corrected the display of database tables in Shared Doc wizard. Increased allowable tables from 16 to 32 and fields from 32 to 64 per table.
  • Eliminated lockup that occurred when copying Special Functions Programs without lines.
  • The user is now prompted to uninstall old versions of software before installing a new version.
  • Added ability to uninstall FTSvrMgr.exe.
  • Add/remove programs has been updated with correct icon.

ControlShop v05/26/05 Release Notes

New Features in S5 Server, v2.03

  • Added support for OPC component categories.
  • Server is now compliant with OPC Data Access Standard Version 2.05A.

Solutions in S5 Server, v2.03

  • Corrected the communication error that occurred when online to a 115U CPU945 PLC and viewing addresses in the data window including I/O byte 16.
  • When the data format is changed by an OPC client, there is no “Data Changed” event that gets sent.
  • Eliminated the error that occurs when launching the server as an OPC server on a machine with no other OPC servers.
  • When the server is running as an OPC server and communications are disconnected, the client will now report the communications problem.

New Features in 505 Server, v2.35

  • Added support for OPC component categories.
  • Server is now compliant with OPC Data Access Standard Version 2.05A.

Solutions in 505 Server, v2.35

  • When the data format is changed by an OPC client, there is no “Data Changed” event that gets sent.
  • Eliminated the error that occurs when launching the server as an OPC server on a machine with no other OPC servers.
  • When the server is running as an OPC server and communications are disconnected, the client will now report the communications problem.

New Features in Mod Server, v2.18

  • Added support for OPC component categories.
  • Server is now compliant with OPC Data Access Standard Version 2.05A.

Solutions in Mod Server, v2.18

  • When the data format is changed by an OPC client, there is no “Data Changed” event that gets sent.
  • Eliminated the error that occurs when launching the server as an OPC server on a machine with no other OPC servers.
  • When the server is running as an OPC server and communications are disconnected, the client will now report the communications problem.
  • Corrected error message that occurs when searching for an invalid address on a TCP/IP network with ladder status on.

New Features in FTLogger, v3.01

  • Added support for OPC Data Access Standard Version 1.0 servers.
  • Added support for OPC component categories.

Solutions in FTLogger, v3.01

  • Eliminated multiple error messages from appearing in the log status window after going offline with an OPC Log Sheet that is using an event logging method.
  • Corrected the problem of opening servers with names greater than 25 characters.
  • Data format options, within the FasTrak Tag and Acknowledge dialogs, now include Discrete, Signed Dec, Unsigned Dec, Hex, Octal, Binary, and Float.
  • 8-bit binary formats now display correctly.
  • Corrected the problem that occurred when OPC tags in the Set Event dialog do not include periods.
  • Eliminated verification errors and exceptions that occurred when offline and selecting OK in the OPC Set Event dialog.

New Features in FTTrend, v2.01

  • Added support for OPC Data Access Standard Version 1.0 servers.
  • Added support for OPC component categories.

Solutions in FTTrend, v2.01

  • Corrected the problem of opening servers with names greater than 25 characters.
  • Data format options now include Discrete, Signed Dec, Unsigned Dec, and Float with no sizes inferred.

New Features in FTAlarm, v4.00

  • Added support for OPC tags.
  • Added support for OPC Data Access Standard Version 1.0 servers.
  • Added support for OPC component categories.

Solutions in FTAlarm, v4.00

  • Corrected the problem of opening servers with names greater than 25 characters.
  • Corrected the problem that occurred when OPC tags in the Set Event dialog do not include periods.
  • Data format options now include Signed Dec, Unsigned Dec, Float, Hex, Octal, Binary, and ASCII with no sizes inferred.
  • Corrected the problem of values not downloading via mouse click on alarm button in graphics mode after loading a file.
  • Corrected the problem of the Alarm Status screen not displaying alarms with a “Comm Error” status when offline and displaying the history of alarm conditions.

New Features in FTBatch, v2.00

  • Added support for OPC tags.
  • Added support for OPC Data Access Standard Version 1.0 servers.
  • Added support for OPC component categories.
  • Added support for SQL databases.
  • Added support for a tag combo box in the Column Setup dialog.
  • Added support for import and export of documentation.
  • Added support for HTML help.
  • Row and column indicators now appear in the status bar.

Solutions in FTBatch, v2.00

  • Data types are now verified against address types before they are changed when manually entering a value and data type in the Batch Sheet or by selecting a new data type from the menu.
  • Corrected the problem of opening servers with names greater than 25 characters.
  • The Batch Sheet no longer displays “XXXXX” in cells where the entire string is not visible.
  • Foreground and background colors within the Batch Sheet have been set to Window system colors.
  • When pressing the Esc (Escape) key while entering a value in the Batch Sheet, changes are now abandoned instead of the value being entered.
  • The Edit box is now activated when entering the ‘-‘ character in a Batch Sheet cell.
  • FTBatch is now able to connect to the documentation databases beyond 32 columns.
  • FTBatch is now able to handle Runtime mode with multiple Batch Sheets.
  • Runtime mode menu now switches to Development mode menu when mode is changed.
  • Filename in the Batch Sheet window title bar is no longer duplicated when a second sheet is created.
  • Eliminated duplicate Batch Sheet names from being created.
  • File name in the Batch Sheet window title bar now changes after performing a Save As.
  • Eliminated the error that occurred when batches were deleted from the middle of a list of batches.
  • Columns now scroll appropriately when the horizontal or vertical scroll bar is moved.
  • The number of batches are now limited to 1024 when connecting to a database.
  • Data format options now include Signed Dec, Unsigned Dec, Float, Hex, Octal, Binary, and ASCII with no sizes inferred.
  • Double clicking a column in the Batch Sheet now expands the column appropriately.
  • Only one instance of FTBatch now runs at one time.
  • Corrected the problem that occurred when OPC tags in the Set Event dialog do not include periods.
  • Eliminated the exception error that occurs when inserting an address into a column.
  • The file name now displays when the screen is maximized.
  • The list of open files now displays within the Windows menu option.
  • Corrected the warning message that appears when loading subsequent files after one file has already been loaded.
  • Corrected the toolbar button display when going online by clicking the toolbar button with more than one Batch Sheet open.

ControlShop v03/03/05 Release Notes

Solutions in S5 Server, v2.02

  • Undefined errors have been replaced with valid OPC errors.
  • Fixed OPC error that occurred when re-adding a group.
  • Fixed error in OPC of function ‘ValidateItems’ not validating the device.
  • Fixed lockup when performing asynchronous OPC reads.
  • Fixed problem with closing an OPC group while performing an asynchronous read.
  • Fixed lockup when performing asynchronous OPC writes in quick succession.
  • Updates are now correct when deactivating, then reactivating groups set to use deadband percents in OPC clients.
  • Fixed handle error when changing two or more consecutive data types in OPC.
  • Fixed problem of OPC function call to SetState failing when changing some of the group settings while ignoring others.
  • Fixed error that occurred during call to OPC function ‘BrowseOPCItemIDs’ using the interface ‘IOPCBrowseServerAddressSpace’ when requesting a filter type of OPC_FLAT.

Solutions in 505 Server, v2.34

  • Fixed OPC error that occurred when re-adding a group.
  • Fixed error in OPC of function ‘ValidateItems’ not validating the device.
  • Fixed lockup when performing asynchronous OPC reads.
  • Fixed problem with closing an OPC group while performing an asynchronous read.
  • Updates are now correct when deactivating, then reactivating groups set to use deadband percents in OPC clients.
  • Fixed handle error when changing two or more consecutive data types in OPC.
  • Fixed the error that occurred when changing the format of an OPC group item from 32-bit to 16-bit.
  • Fixed problem of OPC function call to SetState failing when changing some of the group settings while ignoring others.

Solutions in Mod Server, v2.17

  • Fixed OPC error that occurred when re-adding a group.
  • Fixed lockup when performing asynchronous OPC reads.
  • Fixed problem with closing an OPC group while performing an asynchronous read.
  • Updates are now correct when deactivating, then reactivating groups set to use deadband percents in OPC clients.
  • Fixed the error that occurred when changing the format of an OPC group item from 32-bit to 16-bit.
  • Fixed problem of OPC function call to SetState failing when changing some of the group settings while ignoring others.

New Features in Demo Server, v1.12

  • Added a tray icon that appears when the server is running that provides details about the server and can be used to shut down the server.

New Features in FTLogger, v3.00

  • Added support for OPC tags.
  • Added delay of machine enumeration until the machine combo box drop-down is activated.

Solutions in FTLogger, v3.00

  • Eliminated the potential for lockup when a database error occurs such as a duplicate timestamp.
  • Values are now updated immediately when the format or scaling of an online address is changed.

New Features in FTTrend, v2.00

  • Added support for OPC tags.
  • Added support for SQL databases.
  • Added support for import and export of documentation.
  • Added support for tag combo boxes in real-time and logged data point dialogs.
  • Added support for re-read of documentation within Add/Modify PLC dialog under “Device Source.”

Solutions in FTTrend, v2.00

  • When editing from the Y-Axis Tab of the Graph Settings dialog, the low value no longer resets to 0.
  • Text is now formatted correctly in the list control within the Graph Data dialog.

PLC WorkShop for Siemens S5 v5.11 Release Notes

Solutions

  • Contacts and coils referring to timer and counter addresses now display ladder status correctly.
  • Validating of a stretch flip-flop no longer generates Invalid Cast error message.

PLC WorkShop Suite for Siemens 505 v3.60 SP2 Release Notes

Solutions

  • When pasting into the documentation window, documentation entries are made only for addressees that have documentation.
  • The modem time-out default of 40 seconds may be adjusted from the registry.
  • The location of the ladder cursor, along with the previously searched address, is automatically displayed in the find dialog drop-down.

PLC WorkShop for Siemens S5 v5.10 Release Notes

Features

  • Added support for DB1 Template Distributed I/O on a 95U processor.
  • Added H1 Support.

Solutions

  • Changes to an FB declaration are now reflected properly in the associated FB call(s) of displayed blocks.
  • When importing with German descriptions, addresses are now translated into English prior to import.
  • Comparison feature now compares blocks from 0 to 255; prior to this, the comparison feature compared blocks 0 to 254.
  • Corrected error with clock parameters within the DB1 Template on a 95U processor.

PLC WorkShop Suite for Siemens 505 v3.6 Release Notes

Features

  • Added option to display inline address documentation in Cross Reference Window.
  • Added export and import of Ramp Soak Steps to a text file for use with external editors.
  • Added detailed information to the Access Activity Audit records.
  • Added export and import of V and K addresses to a text file for use with external editors or transfer to another program.
  • Added the ability to copy and paste complete Special Function Programs and Subroutines.
  • In the Find dialog the ‘Search Wrap’ check box now retains its last value.
  • Added the ability to ‘save by parts’ TCP values from the PLC and ‘load by parts’ to the PLC.
  • Added 575 processor indicator (A, B, etc.) in the Status Bar ‘Path’ frame when attached to a 575 processor.
  • Added the ability to replace a range of BITS-of-WORD within the replace table.
  • Added new FTLogger and FTTrend help files to the install tree.
  • Added the ability to delete individual address documentation items from the ‘Edit Documentation’ dialog.

Solutions

  • Page information prints can now follow the left and right margins.
  • TISOFT read-only files can now be opened in 505 Workshop.
  • In NT Security the user name given by the operating system is now the user name displayed in the Activity Audits.
  • The Special Function Compare mismatches are stated more clearly and identify the line numbers that do not match. The comparison will continue until the maximum number of mismatches is found.
  • Corrected problem reading the enabled/disabled and compiled/not compiled Special Functions setting from a TISOFT file.
  • Corrected problem within the Data window using the Fill dialog on a 575 PLC.
  • The Tag and Description is now displayed for register addresses with leading ‘@’.
  • The Tag and Description is now copied with SBR and GTS instructions.
  • The edit boxes within the documentation window can now accommodate longer addresses (i.e. VMM123456).
  • Corrected problem when launching 505 WorkShop by double-clicking a program file.
  • Format of rung comments and descriptions is now consisting upon loading from TISOFT and then exporting back to TISOFT.
  • Deleting a Special Functions Program line online will flag the special function save requirements.
  • Changes to Program Setup will flag the Program Setup save requirement.
  • Clarified wording in the Program Setup – Change Colors: ‘Status Foreground’ is now ‘Status: Instruction Foreground’, ‘Status Optimize Foreground’ is now to ‘Status: Value Foreground’.
  • The print settings are now saved in the registry when pressing the ‘set as default’ button. These settings are then used in a new program and when ‘Restore Defaults’ is used.
  • The ‘Find’ dialog will now inform the user if an illegal search address has been entered.
  • ‘IP Port’in the TCP/IP communications setup dialog has been changed to ‘TCP Port.’
  • Corrected problem with the Data Window going blank when canceling a close program command.
  • Corrected problem with TIWAY ladder status.
  • Profibus slaves are now cleared before downloading new program to PLC.
  • Corrected entering ranges above the configured limit for SBR or GTS address within the replace dialog.
  • Improved dialog message regarding the Cross Reference table not being up to date.
  • Corrected misleading error when message with the ‘Unique Address’ feature.
  • Corrected the error checking for RLL instructions using the DSP register address.

PLC WorkShop for Siemens S5 v5.04 Release Notes

Features

  • Added FTLogger and FTTRend help files to install tree.
  • Hardware security keys for distributors may be updated over the phone or via e-mail.

Solutions

  • Corrected problem importing a particular. NLSW Westing House file.
  • Corrected a misleading security hardware key error message.
  • Corrected problem with print preview ending at a set segment.
  • Correct problem with certain Step 5 headers creating out of bounds arrays.
  • Corrected index error problem when saving a program file from a 115U CPU 945.
  • Corrected a problem with maximum block size causing a timeout when retrieving from the PLC.
  • Corrected problem with mis-matching documentation and ladder in a certain Step 5 file.
  • Corrected a block retrieval problem when deleting a block and then transferring the file online and attempting a new block of PB1.
  • Corrected problem concerning “PLC Clear Memory” utilities when more than one file is open, and at least one is online.

ControlShop v10/29/04 Release Notes

  • We now support Siemens S5 PLC via serial and H1 communictions.

New Features in 505Server, v2.32

  • Hardware security keys for distributors may be updated over the phone or via e-mail.

Solutions in 505Server, v2.32

  • Corrected problem causing the port to remain open after a failed modem communication attempt.
  • Corrected problem with autobauding and voltage spikes using an IBM laptop.

New Features in ModServer, v2.15

  • Hardware security keys for distributors may be updated over the phone or via e-mail.

Solutions in SLC Server, v1.14

  • Correct a timing problem with the Server not closing down properly.

New Features in SLC Server, v1.14

  • A tray icon appears whenever the server is running. Double-clicking on the server icon displays further server information.
  • Hardware security keys for distributors may be updated over the phone or via e-mail.

New Features in PLC5Server, v1.14

  • A tray icon appears whenever the server is running. Double-clicking on the server icon displays further server information.
  • Hardware security keys for distributors may be updated over the phone or via e-mail.

Solutions in PLC5Server, v1.14

  • Correct a timing problem with the Server not closing down properly.

New Features in DemoServer, v1.11

  • A tray icon appears whenever the server is running. Double-clicking on the server icon displays further server information.

New Features in FTAlarm, v3.03

  • Added mili-sec. precision when viewing alarm history.
  • Hardware security keys for distributors may be updated over the phone or via e-mail.

Solutions in FTAlarm, v3.03

  • Corrected problem in export where if you browse and type in a file name with no extension and select ok, the path can get corrupted.
  • Clicking the .ALM file in Windows Explorer automatically launches FTAlarm regardless of file name length.
  • Corrected online problem concerning alarm button that have not been assigned in the graphics view.
  • Corrected button drop text and image displaying vertically-centered instead of horizontally-centered after re-opening a file.

New Features in FTLogger, v2.10

  • Column width in print preview is retained across runs.
  • When spanning files, an option has been added to append the date and time to the filename.
  • Added linear, square root and discrete scaling of log values.
  • File extension type not needed when exporting FTDatawin document.
  • Hardware security keys for distributors may be updated over the phone or via e-mail

Solutions in FTLogger, v2.10

  • Selecting a the .LGR file with a long path name in Windows Explorer correctly launches FTLogger.
  • Corrected problem with the Span File By Time check mark disappearing.
  • Corrected problem in export where if you browse and type in a file name with no extension and select ok, the path can get corrupted.

New Features in FTTrend, v1.40

  • FTTrend can now graph logged data points from spanned log files as one continuous trend.
  • Trend can be saved to a trend history file allowing for a snapshot of the graph for management purposes.
  • When adding a logged data point between separate runs of the application, FTTrend remembers the last log file and path.
  • Hardware security keys for distributors can be updated over the phone or via e-mail.

Solutions in FTTrend, v1.40

  • Corrected problem logging a point from a log file. The description was missing and the pen was not displaying points.
  • Corrected navigation problem when selecting a start time and, or start date that occurred sometime in the past.
  • Clicking the FTTrend file in Windows Explorer automatically launches FTTrend regardless of file path length.
  • Corrected MDI window status when opening a second graph.
  • Can now trend logged data points from the FTTrend database files.
  • Corrected a problem when selecting a logged data point from a databases with several tables and then opening and editing a data point in another table.

New Features in FTBatch, v1.13

  • Hardware security keys for distributors may be updated over the phone or via e-mail.

New Features in FTDataWin, v1.33

  • H1 communications now supported for the S5 PLC.

Solutions in FTDataWin, v1.33

  • Corrected problem in export where if you browse and type in a file name with no extension and select ok, the path can get corrupted.
  • Clicking the .DWN file in Windows Explorer automatically launches FTDataWin regardless of file path length.

PLC WorkShop Suite for Siemens 505 v3.5 Release Notes

Features

  • Exporting of complete address documentation to a CVS file is now available.
  • Support added for the cross-referencing of the SBR instruction.

Solutions

  • Corrected error with SmarTunes and loop printing.
  • Corrected error when replacing a specific call parameter in the Special Function Program.

PLC WorkShop for Siemens S5 v5.02 Release Notes

Features

  • Powerful NT Security – including one-time, server-based Security Configuration, complete Administrator Control of all Editing, Save and Load functions, Documentation, Program Set-Up and Auditing of all user operations.
  • Improved Ease-of-Use with Floating and Docking toolbars, Color Editor, optional Softkey Mode, Shortcut Addressing, Open Tree view programming and improved Context-Sensitive Help.
  • Increased Program Speed due to development and design using full 32-bit implementation.
  • More Powerful Programming with the use of Mnemonics, Merge Blocks, and Cutting and Pasting by block or element.
  • Block Call enhancement with Zoom In/Out, and Previous or Next features.
  • One-step Transfer of Logic from Offline to PLC.
  • Completely redesigned and Expanded Print with Print Preview, Network Cross-Reference and Print-to-Text File.
  • The ability to save Ladder/Statement list and Documentation in a single file which greatly Reduces Disk Space requirements while making it much easier to move files.
  • Expanded Troubleshooting with Network Cross-Reference, Program Compare and a redesigned Data Window.
  • New, built-in SCADA capabilities – including Data Logger and Trender – fully ControlShop compatible.

Solutions

  • Problem having to do with flag saves corrected.
  • “S” values are read only in the Data Window and when Status has been turned on.
  • Problem with Workshop not properly comparing versions when checking for the latest update has been fixed.
  • NT Security will no longer be installed non-NT operating systems.

PLC WorkShop Suite for Siemens 505 v3.40 SP4 Release Notes

Solutions

  • Disabling Activity Audits when pending audit records have not yet been saved no longer causes an “Unable to locate the security server” error.
  • When “Assign Addresses” in Program Setup is selected, Tags are no longer cleared when cursoring off their edit box in the “Edit Documentation” dialog.
  • Output to text file now prints rung Headers longer then three lines
  • Changing PLC Configuration settings now displays a reminder to save the program before closing it.
  • Correct Profibus Slave “I/O Address” values are now retained.
  • Corrected lockup in data window after loading a data template.
  • The structure tree during 505 WorkShop installation automatically selects and retains all nodes.
  • The hardware key driver is now updated during 505 WorkShop installation when an older key driver is detected.
  • Data Window addresses can now be edited after using Ctrl-Home to return to the top of the list.
  • Focus now returns to the Data Window after loading or saving Data Template files.
  • The Cross Reference table now includes the implied addresses used by the Special Function instructions.
  • Complicated printer driver information is now displayed correctly in the ‘Print Setup’ dialog.
  • The “Find” feature now locates all implied VMM addresses.
  • 505 WorkShop now correctly autobauds when attaching to PLCs through serial ports other than COM1.
  • The dialog to edit the Special Function ‘Comment’ instruction uses a fixed font to reflect the way in which the text is held in the PLC.
  • Clearing memory while online via TCP/IP no longer causes a lock-up.
  • Large Special Functions displayed full screen in high resolutions is now allowed.
  • Restoring minimized Windows no longer requires two clicks.
  • A condition in which the Meter Window does not close once the metered activity is complete has been corrected.
  • An option to enable a disabled Special Function appears when its Window is closed.
  • Scrolling through large networks while online no longer causes an “Unknown Network” error.
  • When using TISoft hotkeys in the Logic Window, the “N” key now deletes the horizontal branch at the cursor location and moves the cursor to the right one column.
  • When using TISoft hotkeys in the Logic Window, the ‘J’ and ‘U’ keys now add vertical branches to the left of the cursor and move the cursor up or down one row, respectively.
  • When using TISoft hotkeys in the Logic Window, the ‘M’ key now deletes the vertical branch to the left of the cursor and moves the cursor down one row.
  • Connecting to a PLC through H1 communications no longer brings up unnecessary Dialog boxes.

PLC WorkShop for Siemens S5 v5.01 Release Notes

Features

  • Powerful NT Security – including one-time, server-based Security Configuration, complete Administrator Control of all Editing, Save and Load functions, Documentation, Program Set-Up and Auditing of all user operations.
  • Improved Ease-of-Use with Floating and Docking toolbars, Color Editor, optional Softkey Mode, Shortcut Addressing, Open Tree view programming and improved Context-Sensitive Help.
  • Increased Program Speed due to development and design using full 32-bit implementation.
  • More Powerful Programming with the use of Mnemonics, Merge Blocks, and Cutting and Pasting by block or element.
  • Block Call enhancement with Zoom In/Out, and Previous or Next features.
  • One-step Transfer of Logic from Offline to PLC.
  • Completely redesigned and Expanded Print with Print Preview, Network Cross-Reference and Print-to-Text File.
  • The ability to save Ladder/Statement list and Documentation in a single file which greatly Reduces Disk Space requirements while making it much easier to move files.
  • Expanded Troubleshooting with Network Cross-Reference, Program Compare and a redesigned Data Window.
  • New, built-in SCADA capabilities – including Data Logger and Trender – fully ControlShop compatible.
  • Function Block declaration support added to the statement list AutoHelp.
  • Logic status and user interface response time improved.
  • The .NET framework can be installed automatically from FasTrak SoftWorks website.

Solutions

  • Edit control for home key in Data Window no longer causes the cursor to disappear.
  • Comments for Function Block declarations may include semi-colons.
  • Full functionality of Data Block in Demo mode.
  • Holding the shift key down no longer prevents addresses from being entered in the Data Window.
  • Entering a fill string into the Data Window no longer causes the cursor to jump to the bottom of the Data Window.
  • Column format in the Data Window save template has been corrected.
  • Data Window floating-point format number is now displayed correctly.
  • Corrected problem with updating files using the “closed all documents” under Window Menu.
  • FasTrak authentication security configuration dialog Help link added.
  • Format information retained in Data Window after an undo, clear or cut.
  • Inserting or deleting many rows at the top of the program runs faster.
  • Address column alignment corrected in the Documentation Window and within the Data Window.
  • ASCII values starting with special characters will now open the floating edit.
  • Corrected problem with data editing regaining focus after changing cell to a higher row number.
  • Pop-up menus for NT4.0 are displayed properly in Documentation View and Data View.
  • User is no longer able to type in an invalid range in the Delete Ladder dialog.
  • Autohelp only rebuilds when it is necessary.
  • Corrected problem with the instructions in a parameter not translating the constants properly.
  • The active program does not change after closing all documents from the Window Menu.
  • Complications with the fill command moving the cursor have been corrected.
  • Deleting rows online no longer causes a null reference in the Data Window.
  • Hotkeys for next and previous can be used in the data window.
  • Update problems while using zoom have been corrected.
  • Menu key brings up the right click menu for the Data View, Documentation View or Programming Window.
  • Undo of a segment added to the end of a Function Block will no longer causes an error.
  • Problem with Data Window updating while the Documentation Window is open has been corrected.
  • Clearing the Data Blocks speed has increased.
  • Speed when deleting addresses in the Data Window has increased.
  • The menu item “Logic Status” used to turn status on/off can be selected when the active view is not in Logic View or Edited Logic View.
  • Corrected problem having to do with the Redo of Delete Rows in Data Window causing a null reference.
  • Corrected problem with “data fill” causing infinite loops.
  • Corrected complications with Data Next and Data Previous commands.
  • Cross Reference view’s “Go to Location” functionality will now locate an addresses inside of box instructions.
  • After installation forces a robot the user is no longer asked which products to install again.
  • When selecting “Cancel” from the “products” dialog in the install program, a message no longer comes up asking the user if they would like to install the .NET framework.
  • The “Fill” command is now working correctly.
  • Problem with the slash screen staying up in Windows98 until after the operation is completed has been corrected.
  • Problem in Windows98 with the meter window staying up after the operation is completed has been corrected.
  • Data window no longer permits the address types of T,C, RI,RJ,RS and RT to be viewed in the Data Window.
  • Loading .s5d files and saving them as.fs5 files and then transferring to online was causing the error message “unable to create program. Error writing registers to PLC.”
  • The Function Block declaration comments are now using the statement list comment color instead of using the rung header color.
  • Trying to copy Function Block declaration lines will raise an error message.

PLC WorkShop Suite for Siemens 505 v3.40 SP3 Release Notes

Solutions

  • When Windows 2000 Hot Fix KB824141 was installed, the first key entered in a field in a ladder logic component would be repeated. This has been corrected.
  • The F2 key once again opens the ladder cursor for editing. Use Shift-F2 when editing SF to toggle between enabled and disabled.
  • The Unique Address feature now works on instructions with special addresses, such as timers and counters.
  • Several conditions that could cause application errors have been corrected.
  • The Logic Store Record Not Found condition in Change PLC Type has been corrected.
  • A condition in which downloading to certain older PLCs failed has been corrected.
  • A condition in which an “Unknown communication error” could be generated while downloading WX data has been corrected.
  • A condition where a progress meter window might not close has been corrected.
  • When searching for text in the Documentation Window, the Match Case option is now available.
  • Corrected a condition where entering a PACK instruction with an indirect address caused an SF error.