Month: June 2002

PLC WorkShop for Modicon v5.31 Release Notes

Solutions

  • Corrected problem where attempting an import of a TAB delimited file, while the file is open in EXCEL, gave a sharing violation error, and when doing OK on that error, the import meter bar resides and the software is locked.
  • Corrected problem where the HotKey for Select All, “Ctrl-A” did not work when DOS Hotkeys or Modsoft Hotkeys was turned on.
  • Corrected problem being unable to connect Online to a PLC which has loadables saved in it, and unable to load a file offline which had loadables saved in it. A GPF would occur.
  • Corrected problem where the display of a vertical branch after an up transition, was overwritten when ‘symbol display’ was on and powerflow was showing.
  • Corrected problem where saving a program in Combine mode online in v5.30 caused a GPF.
  • Corrected problem where when double clicking on an FMD file to start PLCWorkShop, the Most Recent Used file list was different than if you just ran the software.
  • Corrected problem where in the TCP/IP comm. Setup, and network scan the user could not enter a 0 for any part of the IP address.
  • Corrected problem where the CR/LF was not recognized during the import of the Modsoft Segment/Network Comment file.
  • Corrected problem when a DX Zoom is done on an instruction, and the instruction contains a 0x discrete, which appears in the zoom window, the 0x discretes cannot be changed to a value of 1. The zoom window will always display a value of 0, even if it is a 1.
  • Corrected problem of being unable to attach Online to older 424 Quantums. Error message “Cannot get object from array” was occurring. Attach to other 424s was OK.
  • Corrected problem where the TCOP module 170-AMM-090 for a Momentum 170CC980-20 did not appear in the TCOP if it was originally entered via Modicon Concept software v2.5.
  • Corrected problem where the output addresses of Quantum TCOP modules with mixed 16 bit inputs and 8 bit outputs, such as (DDM390, DAM390, DAM490, DAM590) could not be configured on BYTE boundaries.
  • Corrected problem where the user was not able to get Online to the TSX Compacts when his key was programmed for Compacts Only. It did work for Offline.
  • Corrected problem where when pasting with rewire at the End of a segment in continuous mode, the network always went to the first network in the segment.
  • Corrected problem where when doing CTRL-L into the documentation editor, in 5-digit address mode, the doc editor did not display the address correctly.
  • Corrected problem where online with a Quantum and adding a NEQN in the last network and cursor off the instruction caused a “Search Failed” error.
  • Corrected problem where opening a FasTrak DOS “.PGR” file containing Peer Cop, did not import the PCOP correctly.
  • Corrected problem where powerflow on a parallel coil did not display correctly.