FTSolution for APT v1.0.2 Release Notes

Features

  • Enhanced demo mode providing the ability to:
    • Import and view APT programs.
    • Create new programs.
    • Edit existing programs.
    • Save demo programs (accessible as demo only).
    • Explore the FTSolution development system.

Solutions

  • Improved the performance of the Forces Window.
  • Added support for the delete key within the Table Editors.
  • Improved support for merging 2BF files.
  • Changed default for the Status Attribute upload box to unchecked.
  • Improved compiler enforcement to only allow a legal number of loops and/or alarms.
  • Improved the error checking within Continuous Function Blocks.
  • Improved the performance of the Mark PCS Tags button.
  • Updated demo mode to restrict print functionality.
  • Improved licensing message when a valid key is not detected.
  • Updated the file import user interface.
  • Updated demo mode restrictions for projects created in licensed mode.
  • Updated demo mode file import default destination path.
  • Updated the Mark a Tag for PCS user interface to clearly differentiate object descriptions from tag descriptions.
  • Updated the Mark a Tag for PCS user interface to display properly in Windows 8.1.
  • Updated the Mark a Tag for PCS user interface to organize information a format more similar to APT.
  • Eliminated incorrect compilation errors when translate is set to Yes.
  • Improved the I/O Module Editor to properly indicate edits to the Bus Parameters.
  • Improved descriptiveness of GSD file parse errors.
  • Eliminated an issue where a promoted SFC could unintentionally lose its promotion.
  • Improved compilation error messaging regarding missing promoted SFCs.
  • Optimized user interface within the SFC Editor to maximize application performance.

FTSolution for APT v1.0.1 Release Notes

Solutions

  • Added error messaging if a user attempts to exceed the maximum number of slaves.
  • Corrected an issue where sampling in debug mode could unexpectedly end the program.
  • Updated the installer to create the proper folder structure for FTSolution for APT.
  • Improved the consistency of naming conventions within the Communications Settings user interface.
  • Improved licensing message when a distributor demo license is detected.
  • Updated the Solution Explorer icons for consistency and clarity.
  • Improved the installer to ensure the installation of .NET 4.0.
  • Updated the compilation errors to match the correct number of reserved loops and/or reserved alarms for each PLC type.
  • Added a prompt during compilation when a user attempts to overwrite an existing project (FSS) file.
  • Updated the Solution Explorer to show the FSS file in the Compile node after compilation.
  • Updated support for 575.5x PLCs.
  • Multiple minor file compilation improvements.

FTVersionTrak for APT v1.7.0 Release Notes

Features

  • Added support for FTSolution for APT integration and files.

Solutions

  • User entry of file path is now allowed during file comparison when local path is selected.

PLC WorkShop for Modicon v5.77 Release Notes

Solutions

  • Corrected a problem that occurred when turning on Floating Doc Window with a NEQN instruction with more than 79 text elements.
  • Corrected a problem that occurred when clearing segments in the Logic editor.
  • Corrected a problem with Output to Text File when Ladder Symbols in Logic dialog box is checked and the Logic dialog box is not selected.

505 Simulator v2.20 Release Notes

Features

  • Added simulation capabilities for PLC WorkShop for Siemens 505 programs that use control relays greater than 32,768.

PLC WorkShop for Modicon v5.76 Release Notes

Features

  • User Interface for the demo is improved; it is now easier to start.
  • Improved the installation procedure for 64-bit operating systems.

Solutions

  • Improved the association of .FMD files with the application; in Windows 7 and 8, double-clicking a .FMD file now consistently opens the file in Modicon WorkShop.

PLC WorkShop for Modicon v5.75 Release Notes

Features

  • An icon for Traffic Cop is now available for the main toolbar. Note:  If the main toolbar has already been customized, it is necessary to manually add the Traffic Cop icon to the main toolbar. If no customization of the main toolbar has been performed, the Traffic Cop icon should appear in the main toolbar automatically upon install.
  • A keyword search is now available in the All Headers program window.
  • Addresses that are used in a program are now identified in the Documentation Window with an asterisk. Previously, there was no way to distinguish used addresses from unused addresses in the Documentation Window.
  • The FTVersionTrak application Product Name is now correctly identified in the Security Key Update dialog box:  FTVersionTrak PE is displayed when FTVersionTrak PE is licensed; FTVersionTrak is displayed when FTVersionTrak is licensed.
  • Modules from OHP Automation Systems are now directly supported in Traffic Cop

Solutions

  • Corrected the display of Segment Number in the Program Window title bar when the Network Number Mode is set to Continuous.
  • Improved the operation/control of specific cursor movements in programs containing Network Equation instructions to prevent an error message.
  • Updated the maximum value of the Watchdog timer for Quantum 434/534 PLCs.

505 Simulator v2.14 Release Notes

Features

  • New instructions for PLC WorkShop for Siemens 505 and CTI 2500 Series processors (MegaEDRUM, Floating Point Comparison, On Delay Coil, and Off Delay Coil) are now supported.

PLC WorkShop for Modicon v5.74 Release Notes

Features

  • The Find feature has been enhanced.
    • The Segment and Network numbers, in which the item was found, are displayed at the top of the ladder logic window.
    • The ladder cursor is placed on the found item.
    • Hot keys and toolbar icons are provided to find the next and previous items.
  • When the Network Cross Reference window is launched, the Cross Reference cursor is placed on the instance of the address on which the Ladder cursor was located.
  • A “Go To Cross Reference” button has been added to the Find results dialog within the Documentation window.

Solutions

  • Traffic Cop has been updated for use with high-speed counters.

PLC WorkShop for Modicon v5.73 Release Notes

Features

  • The updated Sentinel Key Driver is installed with WorkShop for improved Windows support.

Solutions

  • Headers remain visible after editing and scrolling ladder logic.
  • Online help is improved for 16-bit and Extended math instructions.
  • Program accessibility is improved when launching WorkShop from Windows Explorer.
  • Parameter entry for Network Equation NEQN instructions is improved.
  • Legacy hot-key support is restored.
  • The I/O Scan Table is correctly updated.
  • FTVersionTrak support is enhanced.
  • User-selectable parameters in Program Merge are enhanced.

505 Simulator v2.13 Release Notes

Solutions

  • The Lead-Lag instructions are executed correctly when called from Analog Alarms.
  • The Read Slave Diagnostic (RSD) instruction transfers the complete slave’s diagnostic buffer to user memory.
  • The Fall Through Shift Register (FTSR) instruction supports bit-of-word addresses as Status Bits.
  • The Move Image Register From Table (MIRFT) instruction is supported within Master Control Relay (MCR) and Jump (JMP) ladder logic zones.

Modicon Simulator v1.04 Release Notes

Solutions

  • Subtract instruction displays the same values as the PLC.
  • Multiply instruction displays the same values as the PLC.
  • Add instruction displays the same values as the PLC.

PLC WorkShop for Modicon v5.72 Release Notes

Features

  • The toolbar has been updated to support enhanced functionality in the next release of FTVersionTrak.
  • File Comparison may be performed without requiring a program file to be open.
  • Readability of error messages has been improved.
  • Readability of EMTH instruction has been improved.
  • Mouse auto scroll has been enabled within the Data Window.

Solutions

  • Registers not supported by the PLC have been removed from printout not supported by PLC.
  • Accelerator keys in Logic Editor dialog have been improved.
  • Help\Visit FasTrak on the Web menu item links to the FasTrak website.
  • Floating menu describes F3 inserts as Networks/Rows/Columns in ‘FasTrak Hotkeys’.

505 Simulator v2.12 Release Notes

Solutions

  • The correct output states of Compare instructions are retained when the instruction is within jumped networks
  • Image register values of Move Word to Image Registers instructions are unchanged when the instruction is within jumped networks
  • Drum instructions allow time base 0.0 in the SEC/CNT parameter
  • Bit-of-Words for addresses greater than 1024 (for example, V1025, K1025, WX1025) are supported in Special Function Programs and Subroutines
  • Special Function Math instructions support calculations that use long integers
  • Lead-Lag instructions are correctly executed from Special Function Subroutines that are called from Loops, Alarms, or cyclic Special Function Programs
  • The IN parameter of the Search Table for Not Equal instruction accepts all valid address types

PLC WorkShop for Modicon v5.71 Release Notes

Solutions

  • Issues with importing Modsoft program files have been corrected.
  • Adding the 170 AAI 030 00 module in Traffic Cop as an I/O Bus now reserves the proper number of registry addresses.
  • Integration with FTVersionTrak has been improved.

505 Simulator v2.11 Release Notes

Solutions

  • Bit-of-word addresses that exist in SFSUB instructions in the Simulator now properly appear in search results in WorkShop.

 

Modicon Simulator v1.03 Release Notes

Features

  • Selecting the Simulator toolbar icon in WorkShop when Simulator is running will return focus to the Simulator application.

Solutions

  • Micro 612 program files now load into the Simulator without error

PLC WorkShop for Modicon v5.70 Release Notes

Features

  • Users can now import ModSoft version 2.62 project files into WorkShop while offline.
  • A more informative warning message appears when making changes to PLC Configuration.
  • Selecting the Simulator toolbar icon in WorkShop when Simulator is running will return focus to the Simulator application.
  • Data displayed in the Data Window can now be printed directly from the Data Window.
  • The Data Window now displays 16-bit binary values in two groups of 8 bits instead of one 16-bit string.
  • Communications settings can now be stored with the program file.
  • WorkShop now accepts communications settings from FTVersionTrak when an FTVersionTrak user requests to edit or view a WorkShop file with specified communications settings.

Solutions

  • Selecting a Flush Buffer in the ASCII Message Editor now enables the proper text box.
  • Enabling a non-forced contact no longer causes other forced contact to become unforced.
  • Zooming into analog input module 140 ACI 051 00 now displays the correct data format.
  • Modbus Comm Network Access now correctly retains modified settings for serial ports.
  • WorkShop no longer reports an inaccurate memory allocation error when performing a logic search while online.
  • WorkShop no longer closes unexpectedly when Cross Referencing by a 6x register start address when the program does not contain any 6x registers.
  • Text containing spaces that has been copied from the Windows clipboard can no longer be pasted as a documentation tag.
  • PCFL Analog Input Register Flag values are now entered as one word instead of two words.
  • Importing documentation from a *.csv file when the Address Display Size is set to 5 digits now properly updates all imported documentation.
  • Attempting to add an I/O module in Traffic Cop that exceeds the maximum number of I/O points available for the PLC now displays the proper error message.
  • Leaving the ladder cursor on an instruction address for an extended period of time no longer causes the address to change unexpectedly.
  • WorkShop now saves and restores the maximized or minimized state of the logic window.
  • I/O modules 170 ADO 830-30, 170 AMM 110-30, and 170 ADM 850-10 are now supported in Traffic Cop.
  • FasTrak Security no longer allows a program file to be saved when exiting the program if security is configured to disallow saving changes to the program.
  • Performing a search while online no longer returns a “logic store record not found” error when encountering a blank segment.
  • All documentation now prints properly when sorting by tag or description.

505 Simulator v2.10 Release Notes

Features

  • Simulator now supports the following Special Function instructions when simulating the CTI 2500 Series controller:
    • FOR / NEXT
    • WHILE / ENDWHILE
    • SWITCH / BREAK / CASE / DEFAULT / ENDSWITCH
  • Simulator now supports up to 10 parameters for the SFSUB ladder instruction when simulating the CTI 2500 Series controller.
  • Bit-of-word access is now available for Special Function instructions that support expressions, element indexing, or discrete parameters when simulating CTI 2500 Series controllers.
  • Special Function temporary memory size has been increased to 64 when simulating CTI 2500 Series controllers.

Solutions

  • Using the PACK instruction to pack less than 16 bits into a word now properly sets the unused bits to zero when simulating CTI 2500 Series controllers.
  • Lead-Lag instruction results are now consistent across controller types.
  • Users may now add a password to the PLC under FasTrak Security when using the Simulator.